Digital Monitoring Products XR100 Series Programming Guide
42
AreA InformAtIon
Area Information
17.1
AREA INFORMATION
Area Information
Allowsyoutoassignfunctionstothedifferentareasinthesystem.Allnon-24-hour
zonesmustbeassignedtoanactivearea.SeeZoneInformation.
You activate an area by assigning it a name. See Area Name. A name is given
to each active area in place of a number to assist the user during arming and
disarming.TheArmedStatusdisplayis12345678.
17.2
EXIT DELAY: 60
Exit Delay
EntertheexitdelaytimeforallExittypezonesinthisarea.Whentheexitdelay
timestarts,allactivityonthatzoneandothernon-24-hourzonetypesinthearea
isignoreduntiltheexitdelayexpires.ThekeypaddisplaystheExitDelaytime
countdownandannunciatestheExitDelaytoneat8secondintervalsuntilthelast
10secondswhenannunciationisat3secondintervals.
Theexitdelaycanbefrom30to250seconds.Defaultis60seconds.
DuringExitDelay,ifanexitzonetrips,thenrestores,andtripsagain,theExit
Delaytimerrestarts.Thisrestartcanoccuronlyonce.TheExitDelayrestartis
disabledwhenprogrammedforULAAHighLineSecurityoperation.
Exit Error Operation: At arming, whenanentry/exitzone(EX)is faulted at the
end of the exit delay then one of two sequences occur:
ForEntryDelay1EXtypezones:
•thebellsoundsforthelengthoftimesetinBellCutoffprogramming.
•theEntryDelayoperationstartsrequiringcodeentrytodisarm
•ifnotdisarmed,azonealarmandanexiterroraresenttothereceiver.
ForEntryDelay2-4EXtypezones:
•thezoneisforcearmedandazoneforcearmmessageissenttothereceiver
•anExitErrorissenttothereceiver
•thebellsoundsforthelengthoftimesetinBellCutoffprogramming
17.3
BURG BELL OUT: 0
Burglary Bell Output
Entertheoutputnumber(0to6,500to599,G1toG20,orD1toD8)thatisturned
on any time a Burglary type zone is placed in alarm. The output is turned off when
you disarm any area and no other Burglary type zones are in alarm. The output can
alsobeturnedoffusingtheAlarmSilenceoptionintheUserMenuorbyentering
a user code with the authority to silence alarms. The duration of this bell output
follows the time entered in the System Options>Bell Cutoff Time option. See the
Output Options - Bell Cutoff Time section. If Bell Test is selected YES, the Burglary
Bell Output entered here is turned on for two seconds each time the system is
armed.
17.4
O/C RPTS NO YES
Opening/Closing Reports
This option allows an Opening report to be sent to the receiver whenever any area
is disarmed. A Closing report is also sent to the receiver when any area is armed.
17.5
CLS CHK NO YES
Closing Check
SelectYEStoenablethepaneltoverifythatallareasinthesystemarearmed
afterpermanentorextendedschedulesexpire.IftheClosingCheckndsanyareas
disarmed past the sched uled time, the keypads selected to display System Trouble
StatusdisplaysCLOSINGTIME! and emits a steady beep. When Area Schedules is set
toYESinAreaInformation,thespecicareaandnamedisplayfollowedby—LATE.
When Auto Arm is NO, if within ten minutes the system is not armed or if the
scheduleisnotextended,aLatetoClosereportissenttotheSCS-1/SCS-1R
Receiver.WhenAutoArmisYES,theareaarms.SeeAutomaticArmingsection.
If the area becomes disarmed outside of any schedule, the Closing Check sequence
occursaftertheLateArmDelaytime.SeeLateArmDelay.
PC LOG REAL-TIME
STATUS
NO YES