Digital Monitoring Products XR100 Series Programming Guide
32
Bell OptiOns
Bell Options
10.1
BELL OPTIONS
Bell Options
This section allows you to program the panel bell output functions.
10.2
BELL CUTOFF: 15
Bell Cutoff Time
Enterthemaximumtimefrom1to99minutestheBellOutputremainson.Ifthe
areaisdisarmed,thecutofftimeresets.Enter0(zero)toprovidecontinuousbell
output. The default is 15 minutes.
Note: For SIA CP-01 False Alarm Reduction Installations, the Bell Cutoff Time
must be set to a minimum of six (6) minutes.
10.3
BELL TST NO YES
Automatic Bell Test
SelectYEStoturnontheBellOutputfor2secondseachtimethesystem is
com pletely armed from a keypad. This test is delayed until the Closing Wait
acknowledgeisreceived(ifprogrammed).IftheClosingWaitacknowledgeisnot
receivedwithin90seconds,thebelltestdoesnotoccur.Armingperformedfroman
ArmingzoneorfromRemoteLink™doesnotactivatetheBellTest.
10.4
BELL OUTPUT: 0
Bell Output
EntertheoutputnumberwhenneededtofollowthepanelBellOutputoperation
forallactionandoffconditions.Enter0(zero)todisable.
Note:WhenBELLACTIONissettoTforTemporalCode3,theBellOutputactionfor
anLX-Busoutputispulse.
Note:BellOutputshouldnotbeprogrammedforaModel1135WirelessSirenwhen
programmed in Output Information to Trip with Panel Bell.
10.5
BELL ACTION . . . . .
Bell Action
ThissectiondenesthetypeofBellOutputforzonealarms.PressCOMMANDto
display the default Bell Output for each zone type. Press any Select key and enter
SforaSteadyBellOutput,PforaPulsedoutput,TforaTemporalCode3output,
and N for no Bell Output.
Note: Trouble conditions do not activate the Bell Output.
10.5.1
FIRE TYPE: P
Fire Bell Action
DenesBellActionforFireTypezones.ThedefaultisP.
10.5.2
BURGLARY TYPE: S
Burglary Bell Action
DenesBellActionforBurglaryTypezonesandExitErroroutput.Thedefaultisset
at S.
10.5.3
SUPRVSRY TYPE: N
Supervisory Bell Action
DenesBellActionforSupervisoryTypezones.ThedefaultissetatN.
10.5.4
PANIC TYPE: N
Panic Bell Action
DenesBellActionforPanicTypezones.ThedefaultissetatN.
10.5.5
EMERGNCY TYPE: N
Emergency Bell Action
DenesBellActionforEmergencyTypezones.ThedefaultissetatN.
10.5.6
AUXLRY 1 TYPE: N
Auxiliary 1 Bell Action
DenesBellActionforAuxiliary1Typezones.ThedefaultissetatN.
10.5.7
AUXLRY 2 TYPE: N
Auxiliary 2 Bell Action
DenesBellActionforAuxiliary2Typezones.ThedefaultissetatN.