Digital Monitoring Products XR100 Series Programming Guide
34
Output OptiOns
11.6
PANIC ALM OUT: 0
Panic Alarm Output
EntertheoutputnumbertoturnonwhenanyPanictypezoneisplacedinanalarm
condition. The output is turned off after all Panic zones are restored from an alarm
conditionandaSensorResetisperformed.Enter0(zero)todisable.
Wireless Outputs
•ThePanicAlarmiscompatiblewiththeModel1118WirelessRemoteIndicator
LightandtheModel1116WirelessRelayOutputconnectedtoaModel572
IndicatorLED.
•WhenaPanicAlarmoccurs,theLEDturnsonsteadyforveminutesandthen
turns off.
•WhenaPanicTestisinitiatedfromthekeypad,theLEDashesquicklyforve
minutes.
•ForaPanicAlarm,afastresponsewirelessoutputnumberisrecommended.
11.7
AMBUSH OUT: 0
Ambush Output
EntertheoutputnumbertoturnonwhenanAmbushcodeisenteredatakeypad.
TheoutputisturnedoffusingtheSensorResetoption.Enter0(zero)todisable.
11.8
ENTRY OUT: 0
Entry Output
Entertheoutputnumbertoturnonatthestartoftheentrydelaytime.Theoutput
turnsoffwhentheareaisdisarmedortheentrydelaytimeexpires.Enter0(zero)
to disable.
11.9
EXIT OUT: 0
Exit Output
Entertheoutputnumbertoturnonwhenanexitdelaytimestartsinanyareaof
the system. The output turns off when the area arms or when the arming has been
stopped.Enter0(zero)todisable.
11.10
READY OUT: 0
Ready Output
Entertheoutputnumbertoturnonwhenalldisarmedburglaryzonesareina
normal state. The output is turned off when any disarmed burglary type zone is in
abadstate.Enter0(zero)todisable.ThisoutputisnotcompatiblewithCutoff
Outputs.
11.11
PH TRBL OUT: 0
Telephone Trouble Output
Entertheoutputnumbertoturnonwhenthephonelinemonitoronthepanel
phonelineislost.Enter0(zero)todisablethisoutput.
11.12
LATE CLS OUT: 0
Late To Close Output
EntertheoutputnumbertoturnonattheexpirationofaClosingschedule.The
outputactivatessimultaneouslywiththeCLOSINGTIME!keypaddisplay.Theoutput
is turned off when the area is armed, the Closing is extended, or the schedule is
changed.Enter0(zero)todisablethisoutput.
11.13
DVC FAIL OUT: 0
Device Fail Output
Entertheoutputnumbertoturnonwhenanaddresseddevicefailstorespondto
polling from the panel. A Missing Device report is sent to the receiver. The output is
turned off when the device responds to polling or is removed from programming in
thesystem.Enter0(zero)todisablethisoutputandLX-Bus™devicefailreporting
to the receiver. If any addressed device is unsupervised, this output cannot be
used.
11.14
SNSR RST OUT: 0
Sensor Reset Output
EntertheoutputnumbertoturnonwhenaSensorResetisperformedatakeypad.
The output turns off automatically 5 seconds later. This function can be used to
reset smoke detectors that are operated by an external power supply through a
Model716OutputExpanderModule.Enter0(zero)todisablethisoutput.