XR100 Series Programming Guide Digital Monitoring Products
9
CommuniCation
3.6
PATH TYPE: BACKUP
Path Type
ThePathTypedenesifthepathisPrimaryorBackup.BecausePath1isPrimary,
thisoptiononlydisplaysforpaths2-8.DefaultisBackup.
Note:IfthePrimaryCommunicationTypeisCELL,thenthebackupCommunication
TypecanonlybeNET.
3.7
TEST RPT: YES
Test Report
Test Report determines if test reports are sent on this path. Reports are sent
according to the programming in Test Frequency and Test Time. Default is Yes.
SelectYEStoallowtheprogrammedtestreporttobesentonthepathcurrently
being programmed.
SelectDEFERtonotsendatestreportifthepanelcommunicatesanymessage
to the receiver within the time set in Test Frequency. Select NO to not send test
reports on this path.
3.8
TEST FREQ: 1 DY
Test Frequency
TestFrequencydeterminesthefrequencyofthetestreport.Enteranumberfrom1
to60andselectDY(Day)orHR(Hour)bypressingthefarrighttoprowselectkey.
Default is 1 Day.
3.9
TEST DAY: SUN
Test Day
UsethisoptiontosetthedayoftheTestReport.ThisoptionappearsonlywhenTest
Report is Yes, Test Frequency is Day and a multiple of seven. Press the COMMAND key
todisplaytherstfourdaysoftheweek.PresstheCOMMANDkeytodisplaythelast
three days. Select the day of the week to send the test report. Default is Sunday.
3.10
TEST TIME:
0:00 AM
Test Time
UsethisoptiontoselectthetimeofdayforTestReports.Selectthehour,minute
andAM/PM.Enter0:00AMtodisablethisfeature.Defaultis0:00AM.
3.11
CHECKIN: NO YES
Check In
ThisoptiondisplaysiftheCOMMTYPEisNET,orCELL.Check-inreportsarea
methodofsupervisingthepanelforcommunicationwiththereceiver.ForNETthe
defaultisYES.ForCELL,thedefaultisNO.
CHECKIN:
NO YES RND ADPT
SelectRND(Random)forthepaneltocheck-inatrandomtimesfrom6to60minutes
whenallareasaredisarmed.Ifanyareaisarmedacheck-inissentevery6minutes.
SelectADPT(Adaptive)forabackuppathtoadapttothecheck-inprogramming
fromthisgroupsprimarypathiftheprimarypathbecomesunavailable.Check-in
programmingincludesCheck-inandFailTime.
CHECKIN:
ADP3
SelectADP3(Adaptive3)forabackuppathtoadaptusinga3minuteCheck-inand
Fail Time if the primary path becomes unavailable. This option also indicates a
CommunicationTrouble(S10)ifthecelltowerisunavailablefor3minutes.
CHECKIN MINS: 200
WhenYESisselected,enterthenumberofminutesbetweencheck-inreports,from
2to240forNETor3to240forCELL,whenthepanelisarmedordisarmed.For
CELL,thedefaultis0.ForNETthedefaultis200.
3.12
FAIL TIME: 240
Fail Time
ThisoptiondisplaysifCHECKINissettoYES.EnteringaFAILTIMEallowsthe
receivertomissmultiplecheck-insbeforeloggingthatthepanelismissing.The
maximumfailtimeis240minutes.Forexample,ifCHECKINis10andFAILTIMEis
30,thereceiveronlyindicatesaPanelNotRespondingafter30minutes.TheFAIL
TIMEmustbeequaltoorgreaterthantheCHECKINtime.Defaultis0forCELL.
Defaultis240forNET.
3.13
RECEIVER IP
Receiver IP
ThisoptiondisplaysonlyiftheCommunicationTypeisNETorCELL.Enterthe
Receiver IP address where the panel sends network messages. The Receiver IP
Addressmustbeuniqueandcannotbeduplicatedonthenetwork.Enterall12
digitsandleaveouttheperiods.Forexample,enterIPaddress192.168.0.250as
192168000250.Theperiodsdisplayautomatically.