Digital Monitoring Products XR100 Series Programming Guide
30
SyStem OptiOnS
9.19
KEYPAD PANIC KEYS
ENABLED: NO YES
Enable Keypad Panic Keys
Thisoptionallowsthetwo-buttonpanickeyoperationselectedatthekeypadto
sendthePanic,Emergency,orFiremessagetothecentralstationreceiver.Select
YEStoenablethetwo-buttonpanicoperationtooperate.Todisablethetwo-
buttonpanicoperation,selectNO.DefaultisYES.
9.20
OCCUPIED
PREMISE: NO YES
Occupied Premise
ForAll/PerimeterorHome/Sleep/Awaysystems,selectYEStoallowthepanelto
automaticallydisarmtheinteriorarea(s)whenarmingallareasandaperimeter
zone is not tripped during the exit delay. Select NO to disable this feature. Default
isYES.
Note:WithaHome/Sleep/AwaywithGuestarmingsystem,thisfeatureonly
applies to the main system.
9.21
ENHANCED ZONE
TEST: NO YES
Enhanced Zone Test
SelectYEStoallowenhancedzonetestoperation.ThedefaultisNO.
Enhancedoperationallows:
•PanicTestandWalkTestfunctionscanberestrictedtooperateonlyduringan
Area32,Shift4scheduleifprogrammed.Ifnoscheduleisentered,thewalk
test always operates.
•AVerifymessageissenteachtimeazoneistested.Ifazoneistrippedmultiple
times,aVerifymessageissentforeachtrip.ThisallowstheCentralStationto
record the number of devices per zone.
•TheVerifymessageforeachzonetestissentatthetimethetripoccursinstead
of at the end of Walk Test.
•TheSystemTestBeginandSystemTestEndCentralStationmessagesindicate
the type of zone being tested. The System Test Begin message also includes the
user name and number.
9.22
SEND 16 CHAR
NAMES: NO YES
Send 16 Character Names
Thisoptionallowscentralstationstoselectbeingsenteithertherst16characters
ofthenameeldortheentireprogrammedname,upto32characters,foruser
name,userprole,zonename,areaname,outputname,andgroupname.
SelectYEStohavetherst16charactersofthenameeldsenttothecentral
station. Select NO to send the exact number of characters entered in the name
eldfrom1uptothemaximumof32characters.DefaultisYES.
Note:Using32characternamesincreasesthelengthoftheDMPSerial3message
fromthepaneltothereceiver.TheSCS-1Rreceiverdoesnotrequireanupdateto
pass these messages to the Host Automation System of the Central Station. Before
usingnameslongerthan16characters,determinewhethertheHostAutomation
SystemofyourCentralStationcanaccept17to32characternames.Ifnot,only
use16characternames.
9.23
KEYPAD ARMED LED
ALL
Keypad Armed LED
This option displays only when using an Area system. Press any top row key to
selecttheoperationoftheArmedLEDonthekeypad.SelectALLtorequireall
keypaddisplayareastobearmedbeforethekeypadArmedLEDturnson.Select
ANYtoturnonthekeypadArmedLEDwhenanykeypaddisplayareaisarmed.
DefaultisALL.
9.24
USE FALSE ALARM
QUESTION NO YES
Use False Alarm Question
SelectYEStodisplayISTHISAFALSEALARM?NOYESatthekeypadinplaceof
CANCELVERIFYwhenaburglaralarmoccurs.ThisoperatesforALL/PERIMand
HOME/SLEEP/AWAYarmingsystems.DefaultisNO.
9.25
ALLOW OWN USER
CODE CHG? NO YES
Allow Own User Code Change
This option allows users without user code authority to change their own user code.
WhenYESisselected,theUserCodemenudisplaysUSERCODE:*****atthekeypadto
allow that user to change their own code. If NO is selected, the user cannot change
their personal user code. Default is NO.