Digital Monitoring Products XR100 Series Programming Guide
26
SyStem OptiOnS
8.7
ACCESS KEYPADS:
Access Keypads
Selectthekeypadaddresses(1through8)thatsenddooraccessreportstothe
receiver.Enterthekeypadnumberusingthedigitkeys.Anasterisknexttothe
number indicates that the keypad is selected.
A report is sent with each door access made from the selected keypads. Keypads at
addresses not selected still operate the door relay but do not send access reports.
The report includes the user number, user name, keypad address, and device name.
8.8
AMBUSH NO YES
Ambush
YESallowsanambushreporttobesentanytimeusercodenumber1isenteredat
a keypad. NO disables the ambush report and allows user number 1 to operate the
same as all other codes.
System Options
9.1
SYSTEM OPTIONS
System Options
Thissectionallowsyoutoselectsystem-wideparameters.
9.2
SYSTEM: AREA
System
This option allows you to program how the areas operate for arming and disarming.
The options you can choose are listed below:
AREA - All eight areas can be programmed and operated independently.
ALL/PERIMETER -Area1isthePerimeterandArea2istheInterior.
HOME/SLEEP/AWAY -Area1isthePerimeter,Area2istheInterior,andArea3is
theBedrooms.WiththeHOME/SLEEP/AWAYoption,theusercan:
1.SelectHOMEtoarmjusttheperimeter.
2.SelectSLEEPtoarmtheperimeterandinterior(nonbedroomareas).
3.SelectAWAYtoarmallthreeareas.
Note:AHome/Sleep/Awaysystemcanbeconguredtouseallthreeareasor
only use the Home and Away areas.
HOME/SLEEP/AWAY WITH GUEST- This allows the alarm system to be divided into
amainhouseHOME/SLEEP/AWAYsystemandaguesthousethatisalsosetupasa
HOME/SLEEP/AWAYsystem.
Areas1,2,and3arethePerimeter,Interior,andBedroomsfortheMainhouse
system.Areas4,5,and6arethePerimeter,Interior,andBedroomsfortheGuest
system. These areas are automatically assigned per system and cannot be changed.
SeeDisplayAreasinDeviceSetuptoassignkeypadstoasystem.Zonesareassigned
toasystembyassigningthesystem’sareanumberstothezoneinZoneInformation
programming.
WheneitherAll/PerimeterorHome/Sleep/Awayisselected,theareanamesare
automaticallyassignedandcannotbemodied.
Note:Areas3-6inanAll/Perimetersystemandareas4-6inaHome/Sleep/Away
system are not available for use and are initialized.
9.3
INST ARM NO YES
Instant Arming
WhenYESisselected,thearmingkeypaddisplaysINSTANTforselectionduringthe
exit countdown delay when arming fewer than all areas of the system. At the time
instant arming is selected, any entry and exit delays programmed for the areas being
armed are ignored. The entry delay for previously armed areas is not affected by
instant arming. When NO is selected, INSTANT does not display during arming. Default
isNOforanAreaSystem,andYESforanAll/PerimeterorHome/Sleep/Awaysystem.
9.4
CLS WAIT NO YES
Closing Wait
WhenYESisselected,thekeypaddisplaysONEMOMENT...whilewaitingforan
acknowledgementfromthereceiverbeforearmingtheselectedarea(s)and
performingaBellTest(ifselected).ExitdelaysbeginaftertheClosingWait.
Opening/ClosingreportsmustbeYEStoenableClosingWait.
AREA A/P H/A GST