System Link User’s Guide
78
Rpt
(Repeat): The number of times a specific alarm has repeated. The first time a
particular message is received from the same account, the Repeat column displays
0 (zero). When an identical message is received, the Repeat column displays 1
(one). The Repeat count increases in increments of one for each additional signal.
Time:
The time that the alarm signal was received. In case of repeated alarm
signals, the Time column displays the time that the first alarm was received.
Ackn.
(Acknowledge): The time and date the alarm message was acknowledged.
Alarm Message Colors
When the Alarm List first receives an alarm message, the message appears with a violet
background and remains on a violet background until it is acknowledged.
After you acknowledge an alarm message, that message displays on the background color
indicating the type of alarm. The alarm message jumps to the proper location in the Alarm
List while remaining the active message. See Sorting of Alarm Messages.
Violet................ Unacknowledged alarm messages
Red................... Fire Alarm, Fire Trouble, and Fire Restore messages
Yellow ............... Burglary Alarm, Burglary Trouble messages
Green................ Emergency Zone messages
Gray.................. Auxiliary 1 and Auxiliary 2 Zone messages
Orange............... Supervisory Zone messages
Light Green......... Panic Zone messages
Light Yellow ........ Panel System messages and all other messages
Sorting Alarm Messages
When alarm and trouble messages are received, the Alarm List window opens in front of
the other open windows in System Link. The most recent signal received displays on the
top row of the Alarm List.
Messages are sorted by priority. First, they are sorted into acknowledged and
unacknowledged messages, with the unacknowledged signals being at the top of the list.
Within these two categories, signals are sorted by the event type and the time received.
Messages with the highest priority and those received more recently display at the top.
For example, if a fire alarm was received at the same time a zone trouble was received,
the fire alarm would appear above the zone trouble signal. This is to ensure that proper
and timely action is taken on each incoming signal. Messages are prioritized in the
following order:
1. Fire Alarms
2. Panic Alarms
3. Burglary Alarms
4. All Supervisory
5. All Emergency
6. Auxiliary 1 and Auxiliary 2 Alarms
7. Fire Troubles
8. Other Fire (CleanMe™, zone fault, etc.)
9. Other Burglary (zone trouble, zone fault, etc.)
10. All Other Messages (AC fail, low battery, etc.)