User's GuideLT-0570 © 2009 Digital Monitoring Products, Inc. Software Version 1.52 9525
System Link User’s Guide 90Panel Connection Error: Timeout trying to initiate connection with receiver. System Link cannot get a reply from the re
System Link User’s Guide 91 Index 4-2 Communication, 33 About This Manual, 3 AC Power, 53 Access Door, 60, 61 Standard, 61 Access Areas Profil
System Link User’s Guide 92Custom, 70 Data Export, 47 Database Backup, 4, 16 Import, 4, 13, 18 Location, 16 Merge, 19 Purge, 20 Repair, 21 Restore
System Link User’s Guide 93 NET mode, 33 Network Server, 16 New Accounts, 31 No account record, 77 Non-restored alarms, 77 Normal, 53 Not Used, 53
System Link User’s Guide 94Response, 35 Restore Database, 21 Retrieve, 52, 62 Revert, 27 Revert Account, 27 Saved Reports Print, 47 Scanning Proxi
System Link User’s Guide 1 Welcome to System Link Introduction System Link software from Digital Monitoring Products (DMP) gives you the power to m
System Link User’s Guide 2 Computer Requirements Before installing System Link, make sure that your computer hardware meets these minimum specificat
System Link User’s Guide 3 About This Manual How To Use It Any programming options you see on your screen are shown in this manual in a bold font
System Link User’s Guide 4 Safeguarding Your System Link Database Please backup your System Link database on a regular basis! Your System Link datab
System Link User’s Guide 5 Quick Start If you are anxious to get started, this Quick Start guide gives you a brief overview of System Link. The re
System Link User’s Guide 6 Activating System Link You must activate System Link within 7 days of installation. Click Help > Registration to op
System Link User’s Guide 7 Removing a Module If you decide to remove a module from your System Link program, follow the directions below. Note: Y
System Link User’s Guide 8 Quick Connect Connecting Directly to a Panel through a 462N Interface Card or XR500 Series Serial Port To configure Sys
System Link User’s Guide 9 Connecting to a Panel through a Data Network: • Using an XR500N/XR500E/XR2500F panel • Using an XR100N panel • Using
System Link User’s Guide ii
System Link User’s Guide 11 Managing System Link This section discusses how to use System Link software, setup users and accounts, and configu
System Link User’s Guide 13 Getting Started Logging On To log in to System Link, click System > Log On / Off. This opens the Login window. The
System Link User’s Guide 14Receiver Tab The programming options in the System Link Configuration window are available on the following tabs, Receive
System Link User’s Guide 15 Zone#: This field determines how many digits may be assigned to report a zone number. This number should correlate wit
System Link User’s Guide 16Database Tab The settings under the Database tab allow you to change the location where System Link stores data on a comp
System Link User’s Guide 17 If System Link does not start up correctly, one cause could be an invalid database location. Use the command line opti
System Link User’s Guide 18Importing Executive Access Files If you are installing System Link as a replacement for Executive Access, use the import
System Link User’s Guide 19 Merge Database Merge allows you to combine another System Link database with an existing database. Go to System >
System Link User’s Guide iii System Link™ Remote Link™ Software Product License Agreement The terms of this Software Product License Agreement (“SPL
System Link User’s Guide 20Purging the Database Purge allows you to remove System Link activity from the database. When the database resides on a
System Link User’s Guide 21 Restoring the Database The Restore from Backup window automatically appears if you need to restore a corrupt database.
System Link User’s Guide 22Other Tab General Options Time Zones: Under the Other tab, select the appropriate time zone where your System Link comput
System Link User’s Guide 23 Outgoing COM Port: Select the COM port that System Link uses to communicate with your host automation computer. Baud
System Link User’s Guide 24 All operators can add to the list. A prompt appears to confirm addition of the item to the drop down list. Sele
System Link User’s Guide 25 Administrator: Check the Administrator box to provide complete authority to perform administrative functions within Sys
System Link User’s Guide 26Configuring the Toolbar System Link provides a customizable toolbar to assist you when performing common tasks. The toolb
System Link User’s Guide 27 Managing Account Archive Account Archive can be accessed by selecting Panel>Account Archive. The Account Archive fe
System Link User’s Guide 28Managing Accounts If you have a version of DMP's previous alarm panel management software, Executive Access, install
System Link User’s Guide 29 Sorting and Searching Accounts The Name, City, Account, and Panel Phone tabs at the top of the Panel Information window
System Link User’s Guide iv 3. Fees You agree to pay the then-current license fee associated with obtaining a copy of the Software Product. Your
System Link User’s Guide 30Panel Filter Select the Panel Filter button field to filter the information in the panels. Fields: Select the field
System Link User’s Guide 31 Filter Results The results of the filter appear on the Panel Information Filter window. File Name: To export the filt
System Link User’s Guide 32If you uncheck the Programming On File box, the New Panel window changes to show the Main Receiver and Main Account field
System Link User’s Guide 33 In keypad mode, the account number reported to the receiver originates from the panel attached to the iCOMsl. The acco
System Link User’s Guide 34• Modem: Select this option if you are using a computer modem to dial a DMP 462FM 9600 Baud Modem Card installed on the p
System Link User’s Guide 35 • Pickup Only: Select this option to program your System Link computer to answer when the panel calls the receiver. IP
System Link User’s Guide 36Modifying Account Information To edit information on existing accounts, open the Panel Information window by clicking Fil
System Link User’s Guide 37 Copy Existing Account File or Create Templates If you want to create a new account by using an existing account file a
System Link User’s Guide 38Managing Templates The Template tab under Panel Information can be used to create and manage templates of panel programmi
System Link User’s Guide 39 Account Archive Account Archive allows panel account programming to be automatically or manually archived for compariso
System Link User’s Guide v 8. Disclaimer of Warranties The limited warranty that appears above is the only express warranty made to you and is pro
System Link User’s Guide 40Export Account Information To export existing panel account information and programming, click File > Import and Expor
System Link User’s Guide 41 Import Account Information To import existing panel account information and programming, click File > Import and Ex
System Link User’s Guide 42Printing with System Link The Print command allows you to print account, programming, and activity reports and to preview
System Link User’s Guide 43 Printing Activity Reports Prints a report of System Link system activity, such as operators logging in and System Link
System Link User’s Guide 44Printing Events Reports Print a report of events, such as signals and messages received by the Alarm List or events store
System Link User’s Guide 45 Compare Accounts Report This option allows comparison of a variety of panels to each other and/or to a template and a r
System Link User’s Guide 46Sort by Account: Select this option to have the spreadsheet report created where each account is compared to the templat
System Link User’s Guide 47 Select Accounts to Compare: All accounts to be selected for comparison display here. Select the accounts that you wan
System Link User’s Guide 49 Managing Panels with System Link Managing Panels withThe Panel and Program menus c
System Link User’s Guide vi System Link™ © 2000 - 2009 Digital Monitoring Products, Inc. The Information in the user guide is subject to change wit
System Link User’s Guide 51 Panel Menu Use the Panel menu option to contact a panel for programming or downloading. The Panel menu also allows you
System Link User’s Guide 52Retrieving The Retrieve function allows you to retrieve a copy of a subscriber panel's programming, schedules, and u
System Link User’s Guide 53 System Status The System Status option in the Panel menu opens the System Status window. This window allows you to per
System Link User’s Guide 54Alarm Silence The Alarm Silence option allows you to turn off the alarms connected to a panel. To silence an alarm, clic
System Link User’s Guide 55 LX-Bus Diagnostics The LX-Bus Diagnostics window allows you to perform remote diagnostic routines on LX-Bus zones. To
System Link User’s Guide 56Area Status System Link also shows the arm/disarm status of all areas assigned to the panel and allows the user to select
System Link User’s Guide 57 Bad Zone Action During remote arming, some zones in the selected areas may not be in a normal condition. Use the Bypas
System Link User’s Guide 58Zone Bypass / Reset The Zone Status window allows you to use System Link to bypass and reset any zone on the panel. Sele
System Link User’s Guide 59 Outputs Click on the Outputs button in Panel > System Status to open the Output Status window that allows you to vie
System Link User’s Guide vii Table of Contents Welcome to System Link...
System Link User’s Guide 60Door Control The Output Status window also allows you to lock and unlock doors and grant door access events by clicking o
System Link User’s Guide 61 Requesting Events This option allows you to download a panel's event buffer into the System Link database. To op
System Link User’s Guide 62Program Menu Use the Program menu to change programming options in a panel or database file. You must be connected to th
System Link User’s Guide 63 Holiday Dates The Holiday Dates window allows you to enter dates that are used by the Holiday Schedules to override
System Link User’s Guide 64Schedules The Schedules window allows you to schedule individual area auto arming and disarming. You may also create a
System Link User’s Guide 65 XR500 Series, XR100 Series, XR200-485 Enhanced and XR200-485B Enhanced These panels allow the assignment of four indepe
System Link User’s Guide 66Output Schedules Output Schedules allows you to set the times when relay outputs connected to your system turn on and of
System Link User’s Guide 67 Profiles The Profiles window allows you to add, delete, or change user profiles. A profile defines the authority of ea
System Link User’s Guide 68Access Areas: Enter the number for the areas you want to authorize access for this profile. • Areas 1 to 32 for XR500
System Link User’s Guide 69 User Codes The User Codes window allows you to enter or make changes to the user code information in the panel or datab
System Link User’s Guide viii User and Status Programming Tab ...
System Link User’s Guide 70Random (Not Available on XRSuper6): Press the Random button to assign a random number to the user code being entered. T
System Link User’s Guide 71 XR500 Series, XR100 Series, XR200-485 Enhanced, XR200-485 Classic, XR200-485B Profile Number: Enter a number 1 - 99 to
System Link User’s Guide 72Custom Tab Department: Select the department for the current user from the drop down menu. If the required department i
System Link User’s Guide 73 Copying/Pasting User Code Information To copy a user and the user code information to another partition or another pane
System Link User’s Guide 74Batch Import/Export/Delete User Codes The Batch Import/Export User Codes window allows you to import, export and/or delet
System Link User’s Guide 75 Delete User Codes To delete User Codes from the panel file, select the Delete tab. Click on the check box next to t
System Link User’s Guide 76Alarm List Alarm List Window -Requires Alarm Monitoring Module The Alarm List feature of System Link enables you to moni
System Link User’s Guide 77 The Alarm Message List At the top of the Alarm List window, under Visible Alarms, you may select one of three alarm mes
System Link User’s Guide 78• Rpt (Repeat): The number of times a specific alarm has repeated. The first time a particular message is received from
System Link User’s Guide 79 Displaying Account Information When selecting a line in the Alarm List with the mouse cursor, the information for that
System Link User’s Guide ix Program Menu... 62 Holid
System Link User’s Guide 80Acknowledging an Alarm The bottom right corner of the Alarm List contains six buttons to use when responding to an alarm
System Link User’s Guide 81 Connect: Click on this button to open the Connection Status window. This allows you to connect to the panel that sent
System Link User’s Guide 82Report Format You may choose which format you would like to print the events reports. Summary: Prints a report of event
System Link User’s Guide 83 Appendix
System Link User’s Guide 85 Shortcuts Keyboard shortcuts The following keys on the keyboard can be used in a window or a full screen when you are i
System Link User’s Guide 86Time Zones GMT City 0 London, Monrovia, Lisbon, Dublin, Casablanca, Edinburgh 1 Cape Verde Island, Azores 2 Mid-Atlant
System Link User’s Guide 87 Default Profiles Table Number Menu Privilege 1 2 3 4 5 6 7 8 9 10 11-98 99 ARM/DIS NO YES Arm and Disarm No Yes
System Link User’s Guide 88System Link Configuration Record Sheet Please fill in each blank field with the values as they appear in the System Link
System Link User’s Guide 89 Frequently Asked Questions Q. How can I make the modem dial DTMF? A. Enter a check mark in the Tone Dial box in the Sy
Komentarze do niniejszej Instrukcji