System Link User’s Guide
68
Access Areas
: Enter the number for the areas you want to authorize access for this
profile.
• Areas 1 to 32 for XR500 Series or XR2500F panels
• Areas 1 to 8 for XR100 Series panels
Each profile may be assigned door access to specific areas. When profiles 1 to 98 are
created, no areas are assigned by default. By default, profile 99 is assigned authority to all
areas.
To enter an area number, click once in the field to select it and type the number key for
the desired area. That number appears in its place in the field. To remove an area, type
the number that appears in the Access Areas field.
Note: On XR500 or XR100 Series panels set to All/Perimeter or Home/Sleep/Away
operation, Access Areas should be left at factory default settings.
Output Group
: You may assign each profile to an output group number from 1 to 20.
User Menu Assignments
Each user profile may have any of the menus assigned to it as shown in the Profiles table in
the Appendix.
The Profiles table lists the user menu profile assignments and the system functions users
are allowed to access based on the profile numbers assigned to their codes. The settings
listed in the table are default values and any of the profiles can be changed.
Note: Take care that at least one administrator code in your system has a profile with all
authorities and all areas.
Shifts (1 - 4)
: Check the box for each shift where you want to authorize access for this
profile.
Anytime
: Check this box if you would like the profile to operate without regard to
schedules. Selecting Anytime overrides any selections you made in Shifts 1 - 4.
Re Arm Delay
: Allows the entry of 0 to 250 minutes to be used to delay automatic
rearming when the user disarms an area outside of schedule. If zero is selected, the
rearming occurs based on Late/Arm Delay programming in the panel Area Information.
Re Arm Delay is also used to delay a late to close message to the central station when the
panel does not use automatic arming.
If the user has Extend Schedule authority, 2HR 4HR 6HR 8HR displays at disarming. If
the user does not make a choice, the Re Arm Delay is used to extend the schedule.
Applications example: An exit door near the trash is scheduled to be armed at all times.
When the custodian needs to remove trash, program 10 minutes for the activity. Or, an
overhead door only requires access when a delivery is made. Program up to 250 minutes to
allow the loading dock supervisor to load or unload a semi-truck.