Requesting Events
This option allows you to download a panel's event buffer into the System Link database.
To open the Request Events window, select Panel > Request Events.
Note: XR500 Series, XR100 Series, and XR200-485 model panels only. If you are connected
to any version of the XR500 Series, XR100 Series, or XR200-485 panel, the Request Events
window provides two options for what type of events to request from the panel. Check the
boxes in the Request Events window to download Standard and Door Access events
separately.
Standard
: This option requests all events, including Door Access denied events, except
door access.
Door Access
: This option downloads Door Access granted events only.
Select Disconnect on Completion to automatically disconnect from the panel after the
panel’s event buffer is downloaded into the System Link database.
Note: Press the Alt key and F10 key to view the messages in the Diagnostics Window as
the panel receives events. You must open the Diagnostics Window before clicking the
Request button.
To continue, click the Request button. While System Link is
retrieving the events, a status bar appears on your screen that
tracks System Link’s status while downloading.
Each time you request events from a panel, System Link stores
those events in a buffer until you request events again from the
same panel.
Printing the Event Buffer
Once the events have been successfully retrieved, the Request Events Complete window
appears. When you click OK in the Request Events Complete window, a confirm
window appears that says, “Request events complete. Would you like to view the report?”
If you click Yes, the Panel Event Report Setup window appears. From the Panel Event
Report Setup window, you may either print the panel events or preview them on your
computer screen. Turn to page Error! Bookmark not defined. for additional information
on printing the panel event buffer. If you click No, System Link stores the panel events
record in a buffer until you chose to print it or until you download events from the panel
again.
Hanging up
This option is for use after a panel has dropped off line. An attempt to send data to the
panel results in a communication error box.
Selecting Hangup forces the receiver to release the phone line and restore its on-hook
status. Use the Hangup option if the phone line from System Link to the panel is still
connected, but System Link does not acknowledge the connection.
Note: Do not use Hangup to disconnect from a panel while still on line, and the panel is
still responding to System Link. Always use Disconnect to terminate the connection.