System Link User’s Guide
24
All operators can add to the list. A prompt appears to confirm addition of the item to
the drop down list.
Selections are strictly limited to items in the drop down list. Additions can only be
made from the System Link Configuration screen.
Entries for non-Administrative operators are limited to items in the drop down list.
Administrators can enter text not in the drop down list.
Configuring Operators
The programming options in the System Link Operator Configuration window are
available on three tabs, Operator Information, Panel Programming, and User and
Status Programming. To give users authority to log in to System Link, select
System > Operator Configuration.
Operator Information Tab
Login Information:
To authorize a new
operator to log in to
System Link, click on
the New button at the
bottom left corner of
the window. In the
Login Information fields,
enter a Login and
Password for the new
user. At Re-enter
Password retype the
same password to verify.
Each login ID and
password may have up to 32 characters.
Personal Information:
Enter the operator last and first
names.
Account Access:
To authorize the operator to access all
accounts, select All. To restrict the operator to certain
accounts, select Restrict and click the . . . button. In the
Select Accounts window, place a checkmark next to the
accounts the operator is authorized to access.
Note: The Account Access restrict option does not prevent
an operator from using the trap function to send and/or
retrieve changes made by other operators.
Note: When the Account Groups module is enabled, the
Account Access restrict option does not prevent an
operator from adding users and the display only lists
accounts the operator is authorized to access.
User Restrictions:
To limit the operator to view only access. This operator will not have
the ability to program, change or add panel information. Click on the View Only option.