AreA InformAtIon
18.17
LATE OUTPUT: 0
Late Output Number
Enter the output to turn on when this area is not armed by its scheduled time and Area
Late or Closing Time displays at a keypad and the keypad buzzer is on. The output is
turned off when the keypad buzzer is silenced by pressing any key. Default is 0 (zero).
18.18
LATE/ARM DLY: 60
Late Arm Delay
Enter 4 to 250 minutes to delay before automatic re-arming occurs after the area
becomes disarmed outside of schedules. See Closing Check. Default is 60 minutes.
Note: The Late Arm Delay can be superseded by the Re Arm Delay setting of the User
Prole assigned to the user who disarmed the area. Refer to the Re Arm Delay section in
the XR500 Series User’s Guide (LT-0683).
18.19
BANK/SAF NO YES
Bank Safe & Vault (XR500N/XR500E only)
NO disables the Bank Safe & Vault feature for this area. When selected as YES, schedules
set for this area and the time of day cannot be changed while the area is armed.
Program schedules before arming: A Bank Safe & Vault area can only be disarmed
during scheduled times. If the area becomes armed before programming a schedule, the
panel must be reset before the area can be disarmed from a keypad or the Bank Safe &
Vault option in Area Information must be set to NO.
Zones assigned to Bank Safe & Vault areas cannot be bypassed or force armed. Do not
assign Bank Safe & Vault area to an Arming zone. Arming zones can disarm Bank Safe &
Vault areas outside of a schedule.
18.20
COMMON NO YES
Common Area
Select YES to enable this area to operate as a common area. This area is armed when
the last area in the system is armed and is disarmed when the rst area in the system is
disarmed. You can have multiple common areas in each system. For the common area to
work properly, do not assign the common area to any user code. When a user code can
arm and disarm the common area from a keypad at any time, the common area does not
function as a common area.
18.21
ARM FIRST NO YES
Arm First Area
Select YES to enable this area to operate as an Arm First area. This area is automatically
armed when any non-Arm First area assigned to the same keypad is armed but does not
disarm when other areas become disarmed. Assign areas to keypads using the Display
Areas option in Device Setup programming. You can have multiple Arm First areas in a
system and divide them among keypads if needed. If an Arm First area has faulted zones
that cannot be bypassed, arming stops and the areas are not armed. Correct the problem
with the Arm First area and then begin the arming process again. Default value is NO.
Note: The Arm First automatic arming only occurs when arming from a keypad.
Arming from a zone, schedule, or remotely is not affected and Arm First areas do not
automatically arm.
18.22
TWO MAN NO YES
Two Man Rule (XR500N/XR500E only)
Select YES to require two user code entries to disarm and/or allow door access to this
area. When a user presents a code to a keypad or reader requesting a door access or
disarm, 2ND CODE displays and requires the entry of a different user code with at least
the same authority. The second user code must be entered within 30 seconds.
NO disables the Two Man Rule for this area.