45
AreA InformAtIon
18.11
* UNUSED *
Area Name
The area name can be up to 32 alphanumeric characters. To add an area name to the system,
press any Select key and then enter up to 32 characters for the new area name. Press
COMMAND to continue. For instructions on entering alphanumeric characters see section 1.7
Entering Alpha Characters. Inactive areas are marked * UNUSED *. Only systems programmed
for Area arming have the option available to change the area name.
To mark an active area unused, press any top row Select key to delete the old name,
then press the COMMAND key. The programmer automatically programs the name as
*UNUSED*. If you have already cleared Area Information during Initialization, all areas are
marked * UNUSED *. See Initialization section.
Home/Sleep/Away with Guest systems display the area name, but the names cannot be
changed. The following are the display names that appear on the keypad:
Area Display Area Display Area Display
1 Perimeter 4 Guest1 Perimeter 7 Guest2 Perimeter
2 Interior 5 Guest1 Interior 8 Guest2 Interior
3 Bedrooms 6 Guest1 Bedrooms 9 Guest2 Bedrooms
18.12
ACCOUNT NO: 12345
Account Number
Enter the account number to be sent to the receiver for this area. Choose an account
number compatible with the Communication Type selected in Communications. The default
Account Number is the one previously entered in Communications. This account number is
used when sending area messages and events to the central station
.
See the Area Account
Number Messages in the Appendix.
18.13
AUTO ARM NO YES
Automatic Arming
Select YES to allow this area to arm automatically according to permanent, temporary, or
extended schedules. If no schedules are programmed, the area auto arms every hour.
If closing check is selected as YES, the automatic arming function does not take place
until the expiration of a ten minute Closing Check delay. See Closing Check. If the area
has been disarmed outside of any permanent or temporary schedule, the closing check
sequence occurs one hour after the area is disarmed.
At arming, bad zones are handled according to the option selected in section Bad Zones.
If a closing report is sent, the user number is indicated as SCH on the SCS-1R Receiver.
NO disables automatic arming for this area.
Note: For ANSI/SIA CP-01 UL installations, Automatic Arming cannot be used for arming.
18.14
BAD ZONES: BYP
Bad Zones
At the time of automatic arming, some zones in the area may not be in a normal
condition. This option allows you to program the panel response to these bad zones. This
option does not display if AUTO ARM is NO.
BYP FORC REF
BYP - All bad zones are bypassed. A report of the bypass is sent to the receiver if Bypass
Reports is YES. The report indicates SCH as the user number.
FORC - All bad zones are force armed. Zones force armed in a bad condition are capable
of restoring and reporting an alarm if tripped. A forced zone report is transmitted if
Bypass Reports is YES. The report indicates SCH as the user number.
REF - The automatic arming is refused and no arming takes place. A No Closing report is
sent to the receiver regardless of the Closing Check selection.
18.15
AUTO DIS NO YES
Automatic Disarming
NO disables automatic disarming by schedule for this area. When YES is selected, the
area automatically disarms according to permanent or temporary schedules. If an
opening report is sent to the receiver, the user number is indicated as SCH.
Note: For ANSI/SIA CP-01 UL installations, Automatic Disarming cannot be used for
disarming.
18.16
ARMED OUTPUT: 0
Armed Output Number
Enter the output to turn on when this area is armed. If an exit delay is used for this area,
the Armed Output turns on at the start of the exit delay. The output is turned off when
this area is disarmed. The output cannot be turned on from the User Menu Outputs On/
Off option.