Digital Monitoring Products XR500 Series Programming Guide
18
Device Setup
6.14
OVERRIDE NO YES
Schedule Override
Use this option to allow door ON/OFF schedules to be overridden by the armed condition
of the system. Selecting YES causes the on time for a door schedule to be ignored when
all areas assigned to Access Areas for this device are armed. Should any area become
disarmed after the door schedule on time, the device output turns on. A door output
which is on during a disarmed period automatically turns off when all access areas
assigned to the device become armed, even if the scheduled off time has not been
reached. This feature can be used to keep doors locked when a factory opens late, or
is forced to close early, due to a snow storm or other cause. Select NO to allow door
schedules to operate independent of system armed status.
Note: When OVERRIDE is YES and there are no areas programmed in ACCESS AREAS, the
door schedule for that device does not work. Either set OVERRIDE to NO or enter an area
number in ACCESS AREAS.
6.15 Auto Force Arm Device?
Select YES to have all Display Areas assigned to this keypad automatically arm and force
arm faulted zones at arming. The user is not prompted to select areas to arm or force arm
faulted zones after choosing ARM at the keypad. If Closing Code is programmed as YES, only
the matching areas between the Display Areas and the User Code’s authorized areas arm.
Also, when YES is selected, the user is not prompted to select areas to disarm after entering
a code at Entry Delay or after choosing Disarm at the keypad. All matching areas assigned to
the User Code and to this keypad are automatically disarmed. When NO is selected, the user
is prompted to select areas (ALL NO YES) and choose to force arm or bypass at arming and
disarming. Default is NO.
6.16 Door Real-Time Status?
Select YES to have real-time door status messages sent to PC Log reporting and Entré
reporting for this device. Messages are sent anytime the panel turns the door relay on or off.
Default is NO.
6.17 Send Door Forced Message?
Select YES to have the panel send a real-time door status message of Forced Open (FO)
to PC Log reporting and Entré reporting when the door relay is off, but the door zone has
transitioned from its normal state. Default is NO.
6.18 Program 734/734N Options
Select YES to program a 734 or a 734N
/734N-WiFi
Wiegand Interface Module. The options
displayed for a 734 or 734N are the same.
To program the 734, the Device Type must be set to DOOR and the Device Communication
Type must be set to KPD-BUS.
To program the 734N
/734N-WiFi
, the Device Type must be set to DOOR and the Device
Communication Type must be set to NETWORK.
6.18.1 Activate Zone 2 Bypass
Select YES to activate the Bypass option.
Selecting NO allows standard zone operation on Zone 2 and displays the ACTIVATE ZONE 3
REX option. Default setting is NO.
If the door being released by the 734/734N/734N-WiFi module is protected (contact
installed), you can provide a programmable Bypass entry/exit timer by connecting its
contact wiring to the 734/734N/734N-WiFi module Zone 2. When the on-board Form C
relay activates and the user opens the door connected to Zone 2, the zone is bypassed for
the number of seconds programmed in ZONE 2 BYPASS TIME allowing the user to enter/exit.
If Zone 2 does not restore (door closed) within the programmed bypass time, the
734/734N/734N-WiFi piezo pulses during the last ten seconds. If Zone 2 restores prior to
the end of the programmed time, the piezo silences. If the zone does not restore before
the programmed time, the 734/734N/734N-WiFi ends the bypass and indicates the open
or short zone condition to the panel.
6.18.2 Zone 2 Bypass Time
Enter the number of Bypass seconds to elapse before the Bypass timer expires. Range is
from 20 to 250 seconds. Press any top row select key to enter the number of seconds. If
the door remains open when the timer expires a zone open/short is sent to the panel for
Zone 2. The default is 40 seconds.
6.18.3 Relock on Zone 2 Change?
Selecting NO leaves the relay on for the door access time when Zone 2 restores. Selecting
YES turns the 734/734N/734N-WiFi relay off and relocks the door when Zone 2 changes
state. The default is NO.
AUTO FORCE ARM
DEVICE? NO YES
DOOR REAL-TIME
STATUS? NO YES
SEND DOOR FORCED
MESSAGE? NO YES
PROGRAM 734
OPTIONS? NO YES
ACTIVATE ZONE 2
BYPASS? NO YES
ZONE 2 BYPASS
TIME: 40
RELOCK ON ZONE 2
CHANGE? NO YES