Digital Monitoring Products XR500 Series Programming Guide
12
Network optioNs
Network Options (XR500N/XR500E only)
Network Options are provided to dene the network conguration for the panel. This information will be used
during communication of messages via network or email.
Note: IP addresses and port numbers may need to be assigned by the network administrator. When entering an
IP, Gateway, or Subnet Mask address be sure to enter all 12 digits and leave out the periods. For example,
IP address 192.168.000.250 is entered as 192168000250.
4.1
DHCP NO YES
DHCP Mode Enabled
If the panel uses a dynamic IP address select YES. When set to YES, the panel operates
using DHCP and does not use the Local IP Address number. When the DHCP option is set to
NO, the panel uses the IP address entered in Local IP Address. The default value for DHCP
mode is YES.
4.2
LOCAL IP ADDRESS
Local IP Address
192.168.0.250
Enter the local IP address. The Local IP Address must be unique and cannot be
duplicated. The default local IP address is 192.168.0.250.
4.3
GATEWAY ADDRESS
Gateway Address
192.168.0.1
Enter the local gateway address. The Gateway IP Address is needed to exit your local
network. The default gateway address is 192.168.0.1.
4.4
SUBNET MASK
Subnet Mask
255.255.255.000
Enter the local subnet mask assigned to the panel. The default subnet mask address is
255.255.255.000.
4.5
DNS SERVER
DNS Server
192.168.0.1
Enter the IP address of the DNS (Domain Name System) used by the panel to resolve
domain names into IP addresses. The default address is 192.168.0.1.
4.6
PASSPHRASE
-
Passphrase (XR500E only)
To enable encryption type an 8 to 16-character Passphrase using alphanumeric
characters. If you leave the Passphrase blank, the panel communicates with the SCS-1R
Receiver, but the data is not encrypted. The Passphrase is blank by default.
The XR500E panel is capable of communicating encrypted data to an iCOM-E™ Encrypted
Network Alarm Router installed at the receiver. The XR500E panel and the receiver
iCOM-E unit must have the same secret password called a Passphrase.
Note: DO NOT LOSE THE PASSPHRASE. A lost or forgotten Passphrase requires that the
XR500E panel and every iCOM-E unit reporting in to the same iCOM-E unit at the receiver
be individually reprogrammed with a new passphrase.
Note: An XR500E panel communicates using AES encryption. If you currently have an
XR500N panel installed, you may purchase a separate feature key to activate encrypted
communications using the Feature Upgrade process described in the Feature Upgrade
Section. Encrypted communication cannot be enabled on a standard XR500 panel.
4.7
734N LISTEN
734N Listen Port
PORT: 2002
Enter the port number that the 734N/734N-WiFi will use to send communication to
the panel. This must be the same port that is programmed in Panel IP Port within the
734N/734N-WiFi Communication programming menu.
Note: The 734N Listen Port cannot be the same as the panel network programming port.
4.8
734N PASSPHRASE
734N Passphrase
-
Enter an 8 to 16-character Passphrase to encrypt communication with the
734N/734N-WiFi module. The 734N Passphrase must match the 734N Passphrase entered
in Communication programming of the 734N. The Passphrase is blank by default.
Note: A passphrase is required for operation.