1912XR Programming
Page 3
1-INTRODUCTION
1.3 Programmer Operation continued
To select a section for programming, press any one of the top row SELECT keys when the name of
that section is displayed on the keypad. The detailed instructions for each programming step are
found in sections 2 to 15 of this manual.
1.4 Programmer Access Codes
The 1912XR panel allows you to enter the programming function without a code using the steps 1 to
5 listed in section 1.2. We recommend, however, that you install an Access Code that restricts
programming to only those persons your company authorizes. You can do this by using the SET
ACCESS CODE feature in the programmer.
Use this new Access Code to restrict any unauthorized programming of the panel.
Installing an Access Code
After entering the programming function, the keypad displays PROGRAMMER. Press the
COMMAND key to advance through the programming sections until SET ACCESS CODE is
displayed (after STOP). Press any top row SELECT key and then enter a 1 to 5 digit programmer
access code.
Note: There are certain codes used by the panel that cannot be used for an Access Code. When
programming an Access Code, do not:
Enter a number larger than 65,535
Use 6653 (PROG), 2313 (DIAG), or any 3-digit code starting with 98 (such as 984).
These codes must be left available for the panel's use.
Press COMMAND. The displays shows ENTER AGAIN. Enter the new access code again and
press COMMAND. The display shows CODE CHANGED. The new code number must now be
entered before the programmer function can be accessed.
This code number should be kept in a secure place with access limited to only those persons
authorized by your company to program the panel.
Lost Access Code requires factory reset:
If you lose or forget the Access Code, the panel must
be sent back to the factory to be reset. There is no field option for gaining access to the panel
without a valid access code.
1.5 Reset Timeout
The 1912XR has a feature that requires you to enter the Programmer within 30 minutes of resetting
the panel. After 30 minutes, if you attempt to program by entering the 6653 (PROG) code, the
keypad displays: RESET PANEL. You must reset the panel and enter the program code within the
next 30 minutes.
If you are already in the Programmer and do not press any keys on the programming keypad for 30
minutes, the panel terminates programming. As an additional safeguard, all data entered up to that
time is saved in the panel's memory.