Digital Monitoring Products 1912XR Przewodnik Instalacji Strona 1

Przeglądaj online lub pobierz Przewodnik Instalacji dla Systemy kontroli dostępu bezpieczeństwa Digital Monitoring Products 1912XR. Digital Monitoring Products 1912XR Installation guide Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 42
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
123
2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282
MODEL 1912XR
COMMAND PROCESSOR PANEL
PROGRAMMING MANUAL
Do Not Throw Away!
This programming manual contains information you need to program and
service the 1912XR panel and should be kept along with your other DMP
technical documentation.
LT-0171 (10/95)
Przeglądanie stron 0
1 2 3 4 5 6 ... 41 42

Podsumowanie treści

Strona 1 - PROGRAMMING MANUAL

1232841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282MODEL 1912XRCOMMAND PROCESSOR PANELPROGRAMMING MANUALDo Not Throw Away!This

Strona 2

Digital Monitoring Products, Inc.1912XR ProgrammingPage 4 1-INTRODUCTION1.6 Special KeysCOMMAND KeyThe COMMAND key is used to step ahead in program

Strona 3 - TABLE OF CONTENTS

Digital Monitoring Products, Inc.1912XR ProgrammingPage 51-INTRODUCTIONFigure 3: Keypad display and top row keysCenter CharacterLeft CharacterRight Ch

Strona 4

Digital Monitoring Products, Inc.1912XR ProgrammingPage 62-INITIALIZATION2.1 This function allows you to clear selected parts of the panel's memo

Strona 5

Digital Monitoring Products, Inc.1912XR ProgrammingPage 73.1 This section allows you to configure the communication options for the 1912XRpanel. The i

Strona 6 - New and recent additions

Digital Monitoring Products, Inc.1912XR ProgrammingPage 83.2B EXISTING PRINTER - One or more options in Printer Reports has been enabled.See section 1

Strona 7 - Introduction

Digital Monitoring Products, Inc.1912XR ProgrammingPage 93.4 ACCOUNT NUMBER - Enter the account number sent to the SCS-1 Receiver.DD, CID, and HST - T

Strona 8

Digital Monitoring Products, Inc.1912XR ProgrammingPage 103.13 SUPERVISORY/TROUBLE REPORTS - YES enables supervisory, trouble, andtrouble restoral rep

Strona 9

Digital Monitoring Products, Inc.1912XR ProgrammingPage 114.1 This section allows you to define the physical configuration of the 1912XR panel.Enter t

Strona 10 - 1912XR Programming

Digital Monitoring Products, Inc.1912XR ProgrammingPage 125.1 This section allows you to enter the information needed for Remote Command/Remote Progra

Strona 11 - S Y S T E M O N

Digital Monitoring Products, Inc.1912XR ProgrammingPage 135.7 SERVICE RECEIVER AUTHORIZATION - YES enables remote commands andprogramming to be accept

Strona 12

iiMODEL 1912XR PROGRAMMING MANUALCopyright © 1993 – 1995 Digital Monitoring Products, Inc.Information furnished by DMP is believed to be accurate and

Strona 13 - Interface Cards:

Digital Monitoring Products, Inc.1912XR ProgrammingPage 146.1 This function allows you to select the reports the 1912XR sends to the SCS-1Receiver.6.2

Strona 14

Digital Monitoring Products, Inc.1912XR ProgrammingPage 157.1 This section allows you to select system wide parameters used in the operation ofthe 191

Strona 15

Digital Monitoring Products, Inc.1912XR ProgrammingPage 16OUTPUT OPTIONSBELL CUTOFF: 15BELL TST NOBELL ACTION . . . . .SUPRVSRY TYPE: NBURGL

Strona 16

Digital Monitoring Products, Inc.1912XR ProgrammingPage 178.5C COMMUNICATION FAILURE OUTPUT - This output is turned on when any ofthe following condit

Strona 17

Digital Monitoring Products, Inc.1912XR ProgrammingPage 189.1 Menu Display allows you to select at which keypad addresses the user canaccess the follo

Strona 18

Digital Monitoring Products, Inc.1912XR ProgrammingPage 19STATUS LIST10.1 This function allows you to select the loop alarms and troubles, and systemm

Strona 19

Digital Monitoring Products, Inc.1912XR ProgrammingPage 2010.6 SUPERVISORY LOOPS - Specifies the addresses where all supervisory loopalarms and troubl

Strona 20

Digital Monitoring Products, Inc.1912XR ProgrammingPage 2111.1 PRINTER REPORTS - This section allows you to define the operation of a localprinter con

Strona 21

Digital Monitoring Products, Inc.1912XR ProgrammingPage 2212.1 AREA INFORMATION - Allows you to assign functions to the different areaswithin a partit

Strona 22

Digital Monitoring Products, Inc.1912XR ProgrammingPage 23CLS CHK NOACCOUNT NO: 1234512.7 CLOSING CHECK - Enter YES to enable the panel to verify

Strona 23

iiiTABLE OF CONTENTSSectionINTRODUCTIONBefore You Begin ... 1

Strona 24

Digital Monitoring Products, Inc.1912XR ProgrammingPage 2412.15 AUTOMATIC ARMING - Selecting YES allows this area to arm automaticallyaccording to per

Strona 25

Digital Monitoring Products, Inc.1912XR ProgrammingPage 25LOOP INFORMATIONLOOP NO: –13.1 Loop Information allows you to define the operation of e

Strona 26

Digital Monitoring Products, Inc.1912XR ProgrammingPage 26The 1912XR panel contains 12 default loop types for use in configuring the system. These loo

Strona 27

Digital Monitoring Products, Inc.1912XR ProgrammingPage 2713.5 PARTITION NUMBER - Enter the area's partition number where this loop isbeing assig

Strona 28

Digital Monitoring Products, Inc.1912XR ProgrammingPage 2813.7 ALARM ACTION - The Alarm Action section allows you to change the standarddefinitions of

Strona 29

Digital Monitoring Products, Inc.1912XR ProgrammingPage 2913.8C OUTPUT ACTION - Entering an output in section 13.8B displays this prompt thatallows yo

Strona 30

Digital Monitoring Products, Inc.1912XR ProgrammingPage 3013.13 PRIORITY - Selecting YES allows you to provide additional protection for a loopby requ

Strona 31

Digital Monitoring Products, Inc.1912XR ProgrammingPage 31Additional Loop ProgrammingThe remaining Loop Information you need to specify varies with th

Strona 32

Digital Monitoring Products, Inc.1912XR ProgrammingPage 32 STOP14.1 At the STOP prompt, pressing any SELECT key allows you to exit theProg

Strona 33

Digital Monitoring Products, Inc.1912XR ProgrammingPage 3315-SET ACCESS CODE15.1 SET ACCESS CODE - Pressing COMMAND at the Stop prompt displays SETACC

Strona 34

ivTABLE OF CONTENTSSectionREMOTE OPTIONS continuedService Receiver Authorization ...

Strona 35

Digital Monitoring Products, Inc.1912XR ProgrammingPage 3416.1 Events ManagerThe 1912XR Events Manager function allows you to delay sending certain re

Strona 36 - Printer Interface Cards:

Digital Monitoring Products, Inc.1912XR ProgrammingPage 3516.3 Diagnostics functionThe 1912XR panel contains a diagnostics function that allows you to

Strona 37

Digital Monitoring Products, Inc.1912XR ProgrammingPage 361232841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282

Strona 38

vTABLE OF CONTENTSSectionSTATUS LISTStatus List ...

Strona 39

viTABLE OF CONTENTSSectionLOOP INFORMATION continuedOutput Number...

Strona 40

Digital Monitoring Products, Inc.1912XR ProgrammingPage 1 1-INTRODUCTIONIntroduction1.1 Before You BeginAbout this ManualThis manual provides progra

Strona 41

Digital Monitoring Products, Inc.1912XR ProgrammingPage 2 1-INTRODUCTION1.2 Getting Started continuedAccessing the ProgrammerTo access the Programmer

Strona 42

Digital Monitoring Products, Inc.1912XR ProgrammingPage 3 1-INTRODUCTION1.3 Programmer Operation continuedTo select a section for programming, press a

Komentarze do niniejszej Instrukcji