Digital Monitoring Products 1912XR Przewodnik Instalacji Strona 18

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 42
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 17
Digital Monitoring Products, Inc.
1912XR Programming
Page 12
5.1 This section allows you to enter the information needed for Remote Command/
Remote Programming operation.
A description of the Remote Options follow:
5.2 REMOTE KEY - This option allows you to enter a code of up to eight digits for
use in verifying the authority of an alarm or service receiver to perform a remote
command/programming session. The receiver must give the correct key to the
panel before being allowed any remote functions. All panels are shipped from the
factory with the key preset as blank.
To enter a remote key or change the current one, press a top row SELECT key
and enter any combination of up to eight digits. Press COMMAND. The current
key is never displayed.
5.3 MANUFACTURER AUTHORIZATION - Enter YES to allow DMP service
technicians to access the panel when required during system service or
troubleshooting. This authorization automatically expires within one hour.
DMP remote service is provided on a read only basis:
DMP technicians can look at the system
programming and make suggestions only. Alterations can only be accomplished by the installing
company's service personnel.
5.4 ARMED RINGS - Enter the number of rings the panel counts before answering
the phone line when all areas of the system are armed. Any number from 1 to 15
can be entered. If zero is entered, the panel does not answer the phone when all
areas of the system are armed.
5.5 DISARMED RINGS - Enter the number of rings the panel counts before
answering the phone line while any areas of the system are disarmed. Any
number from 1 to 15 can be entered. If zero is entered, the panel does not
answer the phone when any area of the system is disarmed.
5.6 ALARM RECEIVER AUTHORIZATION - Enter YES to enable remote
commands and programming to be accepted from the alarm SCS-1 Receiver.
The Remote Key option can also be required.
With YES selected, the panel requests the receiver key during its first
communication with the first SCS-1 receiver. The panel retains this alarm
receiver key in memory and allows remote commands to be accepted from the
alarm receiver. If an alarm occurs during a remote connect, the alarm report is
immediately sent to this receiver only.
When NO is selected, remote commands and programming are not accepted
from the alarm SCS-1 Receiver.
ALR RCVR NO
RMT KEY:
DISARM RINGS: 0
MFG AUTH NO
5-REMOTE OPTIONS
ARM RINGS: 0
REMOTE OPTIONS