Digital Monitoring Products Graphic Touchscreen Podręcznik Użytkownika Strona 22

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 84
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 21
XR150/XR350/XR550 User’s Guide 15Arming and Disarming
Note: If your system uses a keyswitch to arm an area, the exit
delaytimedoesNOTshowonthekeypaddisplay.
When you arm both the Perimeter and Interior to leave the
building but then you do not exit by the time the exit delay ends,
thesystemautomaticallyarmsbuttheinteriorarea(s)willremain
disarmed because you have not exited.
Should you exit the building and the door does not close properly,
your system may be programmed so that when the exit delay
countdown ends, then the entry delay starts and the bell will sound
to alert you to the situation. Enter your user code to stop the bell
and disarm the system. Rearm the system, exit the building, and
make sure the door is securely closed.
ONE MOMENT . . . Message: If your system is monitored, it
may be programmed to wait for the arming report transmission
to the central station before displaying the armed mes sage. This
veriesyourphonelinesareworkingproperly.Whilethesystemis
waitingforthetransmission,thedisplayreadsONEMOMENT...If
the report is received, the keypad displays the armed message. If
thereportisnotreceived,thekeypaddisplaysLOCALALARMONLY
before displaying the armed message.
Note: Your system may be pre-programmed at installation to:
—sendarmingorzonebypassingreportstoacentralstation
—armand/ordisarmspecicareasatspecickeypads.
Key Fob Arming
Press and hold the key fob button programmed for Arming or the Toggle
arm/disarm button. The Red LED two-second acknowledgement light
indicatesAllSystemOn.TheGreen/Redtwo-secondacknowledgement
lightindicatesSystemOnwithsomeareasarmed.
Key Fob Disarming
Press and hold the key fob button programmed for Disarming
or the Toggle arm/disarm button. The Green LED two-second
acknowledgementlightindicatesAllSystemOff.
Area System Arming Operation
Area Assignment: Your security system has been set up into
separate areas. The number of areas and their names are listed on
the table in System Setup.
Arming the Area System
1. PresstheCOMMANDkeyuntilARMDISARMisdisplayed.
2. Select ARM to arm the system.
3. Enter your user code if required. The keypad displays
ALL?NOYES.
4. SelectNOtoarmonlyselectedareas.Gotostep5.Select
YES to arm all areas authorized for your user code. Go to
step6.
5. IfyouselectedNOinstep4,thedisplaybeginstolisteach
areatowhichyouhaveaccessfollowedbyNOYES.
Example:OFFICENOYES
5a. Select YES for each area you want to arm.
5b. Select NO for each area you do not want to arm.
6. Thesystemdisplaysanybypassedzonesorfaulted24-hour
orPriorityzones.AfaultedPriorityzonecannotbearmed.
7. Atthispointyoucanforcearmorbypassanyfaultedzones.
Azonethatisforcearmedisrestoredintothesystemifitlater
returnsto normal.A zone that is bypassed remains bypassed
until the system is disarmed. See steps 7a through 7d.
7a. If a problem exists on a zone, the zone name and
problemisshownfollowedby:OKAYBYPASSSTOP.
7b. Select OKAYtoforcearmthefaultedzone.
7c. Select BYPASS to bypass all faulted zones being
displayed.
Note:24-hourzonescannotbebypassed.
Przeglądanie stron 21