Digital Monitoring Products XR100 Series Installation Guide
32
WIRING DIAGRAMS
XR100 Series Installation Guide Digital Monitoring Products
33
WIRING DIAGRAMS
35.4 Cellular Backup Installation for Derived Channel Burglary







                  
                      
 
















































Interfacing STU-2Z/STU-4Z to the XR100 Series Panels
The STU-2Z or STU-4Z may only be used in conjunction with telephone
systems that support DCX Systems Derived Channel multiplex network.
The STU-2Z or STU-4Z can only be installed in a DMP Model 350
enclosure.
Burglary
The STU-2Z and STU-4Z are cross listed with the XR100 Series panels
as an accessory for Grade AA Central Station Burglar Alarm. For Grade
AA, the following conditions must be met:
• The panel must be installed and programmed to meet Grade A
burglary alarm system requirements.
• The panel must be installed and programmed for reporting all alarm
conditions through the integral DACT to the same central station
that monitors the STU-2Z or STU-4Z.
• The STU-2Z or STU-4Z must be mounted in the panel enclosure and
wired according to Section 32.4 above.
• Once installed, the central station must enable 2-minute off-hook
polling of the STU-2Z or STU-4Z.
Supplementary Reporting (for Commercial Burglar Alarm
Applications)
The two zones of the STU-2Z or the four zones of the STU-4Z may
be used for supplementary reporting by meeting the following
requirements.
1. Program Relay Output #1 for all alarm conditions that are required
to report alarm on Zone 1 of the STU-2Z or STU-4Z.
2. Program Relay Output #2 for all alarm conditions that are required
to report alarm on Zone 2 of the STU-2Z or STU-4Z.
3. Wire the normally-open terminals of Relay Output #1 to Terminal 1
of the STU-2Z or STU-4Z.
4. Wire the common terminal of Relay Output #1 to Terminal 2 of the
STU-2Z or STU-4Z.
5. Wire the normally-open terminal of Relay Output #2 to Terminal 3
of the STU-2Z or STU-4Z.
6. Wire the common terminal of Relay Output #2 to Terminal 2 of the
STU-2Z or STU-4Z.
Commercial Fire
When the XR100 Series panel is used as a Central Station Alarm
Commercial Fire System with one telephone line, in conjunction with
DCX Systems STU-2Z or STU-4Z, the following conditions must be met:
• The panel must be installed and programmed to meet commercial
re (reporting) systems requirements.
• The panel must be installed and programmed for reporting all alarm
conditions and trouble conditions to the same central station that
monitors the STU-2Z or STU-4Z.
• The STU-2Z or STU-4Z must be mounted in the panel enclosure and
wired according to Section 32.4 above.
• Once installed, the central station must enable 2-minute off-hook
polling of the STU-2Z or STU-4Z.
Installing the STU-2Z/STU-4Z into the DMP Model 350
Enclosure
The STU board is mounted in the left side of the DMP Model 350
enclosure by slipping the optional corner mounting bracket over the
edge of the enclosure. Use DCX Part # 27074-002 (2Z) or Part # 27078-
001 (4Z). Connect the STU power wires and telco cables to the panel
terminals and RJ31X as shown in Section 32.4 above.