BELL OPTIONS
Bell Options
10.1 Bell Options
This section allows you to program the panel bell output functions. If using the Model
1135 or 1135DB Wireless Siren for local annunciation, the Trip with Panel Bell option
should be selected in the Output Information programming for the siren.
10.2 Bell Cutoff Time
Enter the maximum time from 1 to 15 minutes the Bell Output remains on. If the Bell
Output is manually silenced or the system is disarmed, the cutoff time is reset. Enter
zero to provide continuous bell output. Default is 5.
Note: To support the Cancel/Verify operation on an All/Perimeter or Home/Sleep/Away
system, set the Bell Cutoff Time to greater than 0.
10.3 Automatic Bell Test
When YES is selected, the Bell Output is turned on for two seconds when all areas in the
system are armed. The Bell Test only occurs when the areas are armed from a keypad.
Arming performed from an Arming zone or remotely from Remote Link™ does not activate
the Bell Test. In addition, the Closing Wait feature is activated if Opening/Closing Reports
is YES. See OPENING/CLOSING AND USER REPORTS.
Closing Wait operation
Closing Wait provides a delay time before a monitored system arms until the panel
receives an acknowledgment of the closing report from the central station receiver.
During the delay, the keypad displays ONE MOMENT . . . Once the closing is
acknowledged, the keypad buzzes for one second and then displays the ALL SYSTEM
ON message. If the primary communication fails, but the backup communication is
successful, then the message BACKUP ALR ONLY appears. If both primary and backup
communication fail, the message LOCAL ALARM ONLY will appear.
10.4 Bell Output
Enter the output/Favorite number to follow the panel Bell terminal 5 operation for all
action and off conditions. Enter 0 (zero) to disable.
Note: When BELL ACTION below is set to T for Temporal Code 3, this Bell Output action
will be Pulse for wired outputs 1-4, wireless outputs 31-34 and 41-44.
10.5 Bell Action
This denes the type of Bell Action from zone alarms that occurs on the panel’s bell
terminal number 5. Trouble conditions do not activate Bell Action. There are seven zone
types you can program individually for Bell Output. To provide a steady Bell Output,
enter S. For a pulsed output, enter P. For a Temporal Code 3 output, enter T and for no
Bell Output, enter N.
10.5.1 Fire
Denes Bell Action for Fire Type Zones. The default is set at P.
10.5.2 Burglary
Denes Bell Action for Burglary Type Zones. The default is set at S.
10.5.3 Supervisory
Denes Bell Action for Supervisory Type Zones. The default is set at N.
10.5.4 Panic
Denes Bell Action for Panic Type Zones. The default is set at N.
10.5.5 Emergency
Denes Bell Action for Emergency Type Zones. The default is set at N.
10.5.6 Auxiliary 1
Denes Bell Action for Auxiliary 1 Type Zones. The default is set at N.
10.5.7 Auxiliary 2
Denes Bell Action for Auxiliary 2 Type Zones. The default is set at N.
BELL OPTIONS
BELL CUTOFF: 5
BELL TEST NO YES
BELL OUTPUT: 0
BELL ACTION . . .
FIRE TYPE: P
BURGLARY TYPE: S
SUPRVSRY TYPE: N
PANIC TYPE: N
EMERGNCY TYPE: N
AUXLRY 1 TYPE: N
AUXLRY 2 TYPE: N