Digital Monitoring Products XRSuper6/XR20/XR40 Programming Guide
28
zone informaTion
11.9
WIRELESS NO YES
Wireless
Select YES to program this zone as a DMP wireless zone. You must program the
wireless House Code prior to adding wireless zones to the system. See House code
programming in System Options. Default is NO.
11.9.1
SERIAL #: -
Serial Number Entry
Enter the eight digit serial number, including leading zeros, found on the wireless
device.
ALREADY USED Zxx
Displays when the serial number is already programmed for another zone. The
programmed zone number displays.
11.9.2
CONTACT: INTERNAL
Contact
This option displays if the serial number entered is for an 1101 or 1103 Universal
Transmitter or 1114 Wireless Four-Zone Expander. Press any top row key to select
the contact.
INT EXT
This option displays when programming an 1101 Transmitter. Select INT to use the
internal reed switch contacts. Select EXT to connect an external device to the 1101
terminal block. Default is INTERNAL.
By allowing both of the Model 1101 transmitter contacts (INT and EXT) to be used at
the same time, two zones may be programmed from one transmitter. When using
both contacts, you must use consecutive zone numbers.
For example, program transmitter serial number 01345678 as Zone 11 with an INT
contact type and Zone 12 with an EXT contact type. The same serial number is used
for both zones.
CONTACT: x
This option displays when programming an 1114 zone expander which provides four
input contacts. Press any top row key to select the contact. Default is Contact 1.
1 2 3 4
Select the contact number to program. The same transmitter serial number is used
for all four contacts. When using the contacts, you must use consecutive zone
numbers.
For example, use serial number 08345678 to program Contact 1 for Zone 21,
Contact 2 for Zone 22, Contact 3 for zone 23, and Contact 4 for zone 24.
A tamper on the 1114 is transmitted as the zone number assigned to Contact 1.
ALREADY USED Zxx
This message displays when the Contact is already programmed for another zone.
The programmed zone number displays.
NORM OPEN NO YES
The Normally Open option only displays when EXT is selected as the Contact
type. For external devices connected to the 1101 terminal block, select NO to use
normally closed (N/C) contacts. Select YES to use normally open (N/O) contacts.
Default is NO.
Note: For listed installations, set Normally Open to NO.