Strona 1 - Fire Command Center

Fire Command CenterUser’s GuideXR2500F

Strona 2 - Silencing an Alarm

4 XR2500F User’s Guide Introduction User OptionsThe User Options allow you to make adjustments to your keypad to best t your environment and needs.

Strona 3 - Security Command User’s Guide

Introduction XR2500F User’s Guide 5Special Fire Command Center DisplaysAs you use your system, you occasionally see a display that asks you to enter

Strona 4

6 XR2500F User’s Guide IntroductionFAILED TO EXIT (ANTI-PASS BACK) (Burglary Keypad)Anti-passback requires users to properly exit (egress) an area t

Strona 5 - Emergency Evacuation Plans

System Setup XR2500F User’s Guide 7 User MenuFire Command Center User MenuMany of your system features are included in a User Menu you can access f

Strona 6

8 XR2500F User’s Guide System SetupSensor ResetResets smoke or glassbreak detectors. Also clears Fire/Supervisory alarm and trouble displays.Sensor

Strona 7 - Introduction

System Setup XR2500F User’s Guide 9Outputs On OffAllows you to manually turn the system or door access relay outputs ON and OFF.This function is

Strona 8 - The Fire Command Center

10 XR2500F User’s Guide System SetupZone StatusDisplays a list of armed, bypassed, or alarmed zones. Also allows you to check individual zone sta

Strona 9 - Using the Keypad

System Setup XR2500F User’s Guide 11System StatusDisplays the internal system hardware current condition.System Status shows the panel conditio

Strona 10 - Four Function Keys

12 XR2500F User’s Guide System SetupUsing the Panic Zone Test1. Access the User Menu.2. Press COMMAND until SYSTEM TEST? displays.3. Press any Se

Strona 11

System Setup XR2500F User’s Guide 13User Proles ReferenceMenu Display Privilege   DIS      

Strona 12

Copyright© 2000 - 2008 Digital Monitoring Products, Inc.Information furnished by DMP is believed to be accurate and reliable. This information is subj

Strona 13 - User Menu

14 XR2500F User’s Guide System SetupANTI PASS NO Anti-passback requires that you properly exit (egress) an area previously accessed. Whe

Strona 14 - Alarm Silence

System Setup XR2500F User’s Guide 15Adding User Codes1. Access the User Menu.2. Press COMMAND until USER CODES? displays.3. Press any Select key.

Strona 15 - Outputs On Off

16 XR2500F User’s Guide System SetupChanging User Codes1. Access the User Menu.2. Press the COMMAND key until USER CODES? displays.3. Press any S

Strona 16 - Zone Status

System Setup XR2500F User’s Guide 17Ambush CodesYour system may be programmed to allow user number 1 to be used as an Ambush code. This Ambush code

Strona 17 - System Status

18 XR2500F User’s Guide Appendix AAppendix A5. The keypad displays LAST DATE: 10/17. Press any Select key and enter a 4-digit ending

Strona 18 - User Proles

Appendix A XR2500F User’s Guide 19Zone Event DisplaysThis displays alarms, troubles, and other events that may occur on your protection zones.32-Cha

Strona 19 - User Proles Reference

20 XR2500F User’s Guide Appendix ASupervisory Event DisplaysThis displays the date and time of an automatic test report.32-Character Display Descri

Strona 20 - User Codes

Appendix B XR2500F User’s Guide 21Appendix BZone Status BrowserZONE STATUS?ARM BYPS ALR NBRZONE NO: -SELECT ZONE . . .COMMANDAccess the User Menu. P

Strona 21

22 XR2500F User’s Guide Appendix BOutput Groups BrowserSELECT ZONE . . .Access OUTPUT GROUP: - in the USER PROFILES? menu. Press any Select key.At t

Strona 22 - Setting the Date and Time

Appendix B XR2500F User’s Guide 23Change User Proles BrowserUSER PROFILES?ADD DEL CHGPROFILE NO:-1243SELECT PROFILE . . .Access the User Menu. Pr

Strona 23 - Fire Drill

XR2500F User’s Guide iSecurity Command User’s Guidefor XR2500F Command Processor™ PanelsTable of ContentsSection Page Section PageSilencing an Al

Strona 24 - Appendix A

24 XR2500F User’s Guide Appendix BDelete User Codes BrowserUSER CODES?ADD DEL CHGUSER NUMBER:-1243MIKE JONESCO MMA NDAccess the User Menu. Pressth

Strona 25 - Zone Event Displays

Appendix B XR2500F User’s Guide 25Entering User Names-Once you've cleared the defaultname, the display shows a dashon the display left side.To

Strona 26 - System Monitor Event Displays

26 XR2500F User’s Guide Appendix CAppendix CCommon Keypad DisplaysListed below are several keypad messages you may see on the display. Follow the i

Strona 27 - Appendix B

Index XR2500F User’s Guide 27A15235552817

Strona 28 - Outputs On/Off Browser

28 XR2500F User’s Guide Index1744444I55

Strona 29 - Add User Codes Browser

This page intentionally left blank.

Strona 30 - Change User Codes Browser

8415LT-0760 1.01 © 2008 Digital Monitoring Products, Inc.

Strona 31

ii XR2500F User’s Guide Appendix B ... 21 ...

Strona 32 - Appendix C

XR2500F User’s Guide iiiThe National Fire Protection Association recommends that you establish an emergency evacuation plan to safeguard liv

Strona 33

iv XR2500F User’s Guide This page intentionally left blank

Strona 34

Introduction XR2500F User’s Guide 1IntroductionA Remote Fire Command Center is also available to use with the XR2500F Addressable Fire

Strona 35

2 XR2500F User’s Guide IntroductionThe Fire Command Center Your system comes equipped with a built-in, easy-to-use Fire Command Center that

Strona 36

Introduction XR2500F User’s Guide 3Asterisks in Burglary Area Armed DisplaysAsterisks display next to a programming option that is already