Digital Monitoring Products XR150/XR350/XR550 Series Programming Guide
62
APPENDIX
PN (Panic zone)
Used for connecting to mechanical devices that allow a user to signal an emergency alarm. Panic zones can
provide either a silent or audible alarm with or without reporting to a central station receiver.
EM (Emergency zone)
These are used for reporting medical or other non-panic emergencies to the central station receiver.
SV (Supervisory zone)
Used to provide 24-hour zone supervision to devices associated with re systems. Typical applications are
tamper switches on Post Indicator Valves (PIVs), gate valves, and low and high temperature gauges.
FI (Fire zone)
Used for any type of powered or mechanical re detection device. Typical applications are for smoke
detectors, sprinkler owswitches, manual pull stations, and beam detectors. Retard, cross zoning, and
presignal options are available for the Fire zone type.
FV (Fire Verify zone)
Used primarily for smoke detector circuits to verify the existence of an actual re condition. When a Fire
Verify zone initiates an alarm, the panel performs a Fire Reset. If any Fire Verify zone initiates an alarm
within 120 seconds after the reset, an alarm is indicated. If an alarm is initiated after 120 seconds, the cycle
repeats.
A1 and A2 (Auxiliary 1 and Auxiliary 2)
These zones are similar to a Night zone and are typically used to protect restricted areas within a protected
premises.
AR (Arming zone)
This zone allows you to connect a keyswitch to a zone and use it to arm and disarm one or more areas.
22.12 ZoneTypeSpecications
The panel contains multiple default zone types for use in conguring the system. These zone types provide
the most commonly selected functions for their applications. All zone types can be customized by changing
the variable options listed below. The Keypad Bus Zone Information table below reects the zone types for
Keypad Bus Zones. The LX-Bus Zone Information table on the next page reects the zone types for LX-Bus
Zones.
Keypad Bus Zone
Information
Type Area Fire
Bell
Disarmed
Open
Disarmed
Short
Armed
Open
Armed
Short
Swinger
Prewarn
Entry Delay
Retard Delay
Presignal
Fast Response
Cross Zone
Priority
Follow Area
Real-Time Rprts
Door Number
Style
Assign Disarm condition of
NT, DY, EX, A1, and A2 only
Assign Prewarn and Entry
Delay for EX only
Assign Retard and Presignal
for FI, SV, A1, and A2 only
Zone Type Defaults
--
DY
FI
NT
EX
PN
SV
A2
AR
INT
PERIM
BDRM
or
1
to
32
Output *
Message
Output *
Action
Message
Output *
Action
Message
Output *
Action
Message
Output *
Action
A
T
L
-
D
S
C
S
P
M
F
A
T
L
-
D
S
C
S
P
M
F
A
T
L
-
D
S
C
S
P
M
F
A
T
L
-
D
S
C
S
P
M
F
N
or
Y
1
to
16
1
or
4
N
or
Y
1
to
16
N
or
Y
N
or
Y
N
or
Y
0
to
16
N
or
Y
0
to
16
TGL
ARM
DIS
STEP
MNT
Night NT - 0 S - 0 S A 0 S A 0 S Y N N N 0 N 0
Day DY T 0 S T 0 S A 0 S A 0 S Y N N N 0 N 0
Exit EX - 0 S - 0 S A 0 S A 0 S Y
1-16
1 N N N N 0
Fire FI 0 T 0 S A 0 S N N + N N N
Panic PN T 0 S A 0 S N N N N
Emergency EM T 0 S A 0 S N N N N
Supervisory SV 0 T 0 S A 0 S N N + N N N
Auxiliary 1 A1 T 0 S A 0 S T 0 S A 0 S N N + N N N 0 N 0
Auxiliary 2 A2 T 0 S A 0 S T 0 S A 0 S N N + N N N 0 N 0
Fire Verify FV 0 T 0 S A 0 S N N N
Arming AR TGL
*Output Options: 1 to 6, 450 to 474, 480 to 499, 500 to 999, D1 to D16, F1 to F20, G1 to G20. + = Set retard to YES before selecting presignal. = Zone functions not available.