Digital Monitoring Products 7073A Dokumentacja Strona 8

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 8
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 7
7073A Operating Manual
Genelec Document
D0049R001
. Copyright Genelec Oy 4.2003. All data subject to change without prior notice
International enquiries:
Genelec, Olvitie 5
FIN-74100, Iisalmi, Finland
Phone +358 17 83 881
Fax +358 17 812 267
Email genelec@genelec.com
In the U.S. please contact
Genelec, Inc., 7 Tech Circle
Natick, MA 01760, USA
Phone +1 508 652 0900
Fax +1 508 652 0909
Email genelec.usa@genelec.com
www.genelec.com
7073A
Subsonic filter
(18 dB/octave) below 19 Hz
Upper bandwidth/LFE cutoff 85 Hz/120 Hz selectable
Crossover frequency,
(sub/main channels) 85 Hz
Crossover slopes
Lowpass 36 dB/octave
Highpass 12 dB/octave
Midband rejection >400 Hz
50 dB
Bass roll-off control operating From 0 to –6 dB @ 20 Hz
range in 2 dB steps
Phase matching control From 0 to 270° @ 85 Hz
in 90° steps
AMPLIFIER SECTION
INPUT SECTION
CROSSOVER SECTION
SYSTEM SPECIFICATIONS
7073A
Free field frequency response 19 Hz…85 Hz
(+/- 3 dB) LFE 85/120 Hz
Maximum short term sine wave
SPL output averaged from
30 to 85 Hz, measured in
half space at 1 meter
124 dB SPL
Maximum peak SPL output with
random pink noise, measured
in half space at 1 meter
129 dB SPL
Self generated noise level in
free field @ 1 m on axis
(A-weighted)
20 dB
Harmonic distortion @ 105 dB SPL
at @ 1 m on axis in half space 30 … 85 Hz
2nd
2 %
3rd
2 %
Drivers 4 x 305 mm (12”)
Weight 120 kg (265 lbs)
Dimensions
Height 524 mm (20 5/8”)
Width 1440 mm (56 11/16”)*
Depth 558 mm (22”)
* If the subwoofer is flush mounted into a wall or a cabinet, the
recess must be 20 cm (8”) wider than the subwoofer to allow
sufficient clearance for the reflex port situated at the end of the
subwoofer enclosure.
7073A
Short term amplifier output
power (Long term output power
is limited by driver unit
protection circuitry) 1000 W
Amplifier system distortion
at nominal output
THD
0.05%
Mains voltage 100 / 200V
or 115 / 230V
Power consumption (average)
Idle 60 VA
Full output 1000 VA
OUTPUT SECTION
CONTROLS
7073A
Free field frequency response 19 Hz…85 Hz
(+/- 3 dB) LFE 85/120 Hz
Harmonic distortion @ 105 dB SPL
at @ 1 m on axis in half space 30 … 85 Hz
Drivers 4 x 305 mm (12”)
Weight 120 kg (265 lbs)
Height 524 mm (20 5/8”)
Width 1440 mm (56 11/16”)*
Depth 558 mm (22”)
7073A
(18 dB/octave) below 19 Hz
Upper bandwidth/LFE cutoff 85 Hz/120 Hz selectable
(sub/main channels) 85 Hz
Lowpass 36 dB/octave
Highpass 12 dB/octave
Bass roll-off control operating From 0 to –6 dB @ 20 Hz
range in 2 dB steps
Phase matching control From 0 to 270° @ 85 Hz
7073A
protection circuitry) 1000 W
Mains voltage 100 / 200V
or 115 / 230V
Idle 60 VA
Full output 1000 VA
7073A
Input connector XLR female
pin 1 gnd
pin 1 gnd
pin 2 +
pin 2 +
pin 3
pin 3
Input impedance 10 kOhm balanced
Input impedance 10 kOhm balanced
Input level for 100 dB SPL
output @ 1 m Variable from +6 to –12 dBu
output @ 1 m Variable from +6 to –12 dBu
7073A
Output connector XLR male
Output connector XLR male
pin 1 gnd
pin 1 gnd
pin 2 +
pin 2 +
pin 3
pin 3
Remote LED connector (RJ11) Remote LED for
Remote LED connector (RJ11) Remote LED for
Power/Overload+Bypass
Power/Overload+Bypass
Main monitor Out gain 0 dB
Main monitor Out gain 0 dB
Sum/Link Out gain 0 dB
Sum/Link Out gain 0 dB
7073A
7073A
Input sensitivity +6 to –12 dBu
Input sensitivity +6 to –12 dBu
Bass roll-off 0/-2 dB/ -4 dB/ -6 dB@ 20 Hz
Bass roll-off 0/-2 dB/ -4 dB/ -6 dB@ 20 Hz
Phase 0 / 90 / 180 / 27
Phase 0 / 90 / 180 / 27
LFE/upper bandwidth limit 85 / 120 Hz selectable
LFE/upper bandwidth limit 85 / 120 Hz selectable
Bypass Bypasses the bass
Bypass Bypasses the bass
management for the
management for the
main channels
main channels
LFE sensitivity 0 / +10 dB
LFE sensitivity 0 / +10 dB
Redirect Redirects LFE channel signal
Redirect Redirects LFE channel signal
above 85 Hz to center channel
above 85 Hz to center channel
Sum in Changes subwoofer to
Sum in Changes subwoofer to
Sum in mode
Sum in mode
Test tone for phase adjustment 85 Hz
Test tone for phase adjustment 85 Hz
In China please contact:
Genelec China Representative Office
Soho New Town, 88 Jianguo Road
D-1504, Chaoyang District
Beijing 100022, China
Phone +86 10 8580 2180
Fax
+86 10 8580 2181
Przeglądanie stron 7
1 2 3 4 5 6 7 8

Komentarze do niniejszej Instrukcji

Brak uwag